IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Full Load Amps-Inductive 32 A
Full Load Amps-Resistive 50 A
Number of Poles 3
Coil Volts 120 V AC
Reversing No
HP @ 1 Phase - 120V 2 hp
HP @ 1 Phase - 240V 5 hp
HP @ 3 Phase - 208V 10 hp
HP @ 3 Phase - 240V 10 hp
HP @ 3 Phase - 575V 30 hp
HP @ 3 Phase - 480V 20 hp
Enclosure NEMA Rating No Enclosure
Aux. Contact Configuration 1NO/1NC
Hz 50/60
Auxiliary Contact Form 1NO/1NC
Frame / Series / Class / Code TeSys
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Series TeSys Deca
Operating Speed 3600 cycles per hr
Rated Voltage 690V AC, 300V DC
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
IP Rating IP20
Inrush VA 70 VA
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Max. Operating Watts 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Rated Breaking Capacity 550 A @ 440V
Switching Current 5 mA (Signalling Circuit)
Non-Overlap Time 1.5 ms
Includes Protective Cover Yes
Fire Rating UL 94 V1
Fuse Amps 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Electrical Durability 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V); 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Net Weight 0.375 kg
Impedance 2 mOhm
Electrical Connection Screw Clamp Terminals
Impulse Withstand Voltage 6 kV
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Thermal Amperage 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Features Without Built-In Suppressor Module
Tightening Torque 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Overvoltage Category CAT III
Max. Temperature 850°C
Mounts On Plate, Rail
Mechanical Durability 15 Mcycles
Rated Insulation Volts 600/690V
Switching Voltage 17 V (Signalling Circuit)
Rated Short-Time Withstand Current 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Signalling Circuit Frequency 25 to 400 Hz
Shock Resistance 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Watts Loss 2 to 3W
Application Motor Control, Resistive Load
Horsepower @ Three Phase - 208V AC 7 1/2 hp
Full Load Current - Inductive 32 A
NEMA Enclosure Rating No Enclosure
Includes Auxiliary Contacts Yes
Maximum Voltage Rating 690V AC
Electrical Operating Durability 1,400,000, 1,650,000
Minimum Operating Temperature -40 Degrees F
Terminal Connection Type Screw Clamp Terminals
Coil Voltage 120V AC
Horsepower @ Single Phase - 120V AC 2 hp
Full Load Current - Resistive 50 A
Reversing Capability Non-Reversing
Horsepower @ Single Phase - 240V AC 5 hp
Resistance Properties Fire Resistant, Insulation Resistant
Contactor Style IEC
Number of Normally Open Main Contacts 3
Horsepower @ Three Phase - 240V AC 10 hp
Horsepower @ Three Phase - 600V AC 30 hp
Mounting Style DIN Rail, Plate
Mechanical Operating Durability 15,000,000
Embedded Surge Suppressor No
Frequency 50/60 Hz
Maximum Operating Temperature 140 Degrees F
Phase Three
Horsepower @ Three Phase - 480V AC 20 hp
Number of Auxillary Contacts 2