Voltage |
20/30VAC |
Stages Heat |
3 |
Mounting Type |
UWP Mounting System |
Mounting Location |
Wall |
Color |
White |
Control Range |
Heat 40 Degrees F to 90 Degrees F; Cool 50 Degrees F to 99 Degrees F |
System Switching |
Auto-Heat-Cool-Off-Emergency |
Stages Cool |
2 |
Dual Transformer Compatible |
No |
Power Method |
Hardwired/Battery |
750mV Compatible |
No |
Programs per Week |
7, 5-2, 5-1-1 |
Humidification Control |
No |
Temporary Program Override |
Yes |
Low Battery Indicator |
Yes |
Batteries Included |
Yes |
Terminal Designations |
RC, R, C, W, W2, AUX, Y, Y2, O/B, G, K, E, U, U, L/A, S, S |
Programmable Fan |
Yes |
Temporary Temperature Hold |
Yes |
Features |
Programmable, Universal Mounting |
Automatic Changeover |
Yes |
Temperature Limiting |
No |
Key Pad Lockout |
No |
Display Color |
Blue |
Dehumidification Control |
No |
WiFi Capability |
No |
Footnotes |
1, 3, 6, 7 |
Display Type |
Backlit |
Fan Switching |
Yes |
For Use With |
Gas, Oil or Electric Heat with A/C, Warm Air, Hot Water, High-Efficiency Furnace, Heat Pumps, Steam, Gravity |
Filter Indicator |
No |
Temp. Settings per Day |
0, 1, 2, 4 |
Includes |
Universal Wall Plate Mounting System, Mounting Hardware, J Box Adapter, Decorative Cover Plate, Installation Instructions and User Guide |
Battery Backup |
Yes |
Remote Sensing Capability |
Yes |
Control Type |
Push Button |
Stages |
2H/2C Conventional, 3H/2C Heat Pump |
Mounting Direction |
Horizontal |
Number of Heating Stages - Conventional System |
2 |
Number of Heating Stages - Heat Pump System |
3 |
Operating Temperature Range |
32 Degrees to 120 Degrees F |
Application |
Heat and Cool |
Backlit Screen |
Yes |
System Settings |
Auto-Cool-Emergency Heat-Heat-Off |
Minimum Operating Humidity |
5 % |
Maximum Control Temperature |
99 Degrees F |
Maximum Operating Temperature |
120 Degrees F |
Backlit Screen Color |
Blue |
Temperature Readout |
Yes |
Contact Rating |
20/30V AC |
Minimum Operating Temperature |
32 Degrees F |
Temperature Differential |
1 Degrees F |
Frequency |
50 Hz, 60 Hz |
Number of Zones |
1 |
Filter Change Reminder |
No |
Operating Humidity Range |
5% to 90% RH |
Programming Capability |
5-1-1, 5-2, 7 Day |
Compatible System Type |
Gas Forced Air Furnaces, Heat Pump with Aux, Hydronic Systems, Electric Forced Air Furnaces |
Millivolt Compatible |
No |
Temperature Scale |
Fahrenheit/Celsius |
Mounting Direction/Shape |
Square |
Changeover Type |
Automatic |
Includes Positive Off |
Yes |
Temperature settings per day |
0, 1, 2, 4 |
Minimum Control Temperature |
40 Degrees F |
Application/Stages |
Heat and Cool; 2H/2C Conventional, 3H/2C Heat Pump |
Number of Cooling Stages - Conventional System |
2 |
Shape |
Square |
Includes Batteries |
Yes |
Thermostat Type |
Low Voltage |
Fan Settings |
Auto-Circulate-On |
Sensor Location |
Remote |
Maximum Operating Humidity |
90 % |
Temperature Control Range |
40 Degrees to 99 Degrees F |
Number of Cooling Stages - Heat Pump System |
2 |
Electrical Connection Type |
Hardwired |
System/Fan Settings |
Auto-Cool-Emergency Heat-Heat-Off/Auto-Circulate-Follow Schedule-On |