Digital/Analog |
Digital |
Max. AC Amps |
2,000 |
Clamp Meter Jaw Style |
Clamp On |
Max. DC Volts |
1,000 V |
Max. Ohms |
40 megaohm |
Jaw Capacity |
2.0 in (51 mm) |
Safety Rating |
CAT IV 600V |
Display |
LCD |
Jaw Opening |
2 in |
Max. DC Amps |
400 |
Max. AC Volts |
1,000 V |
Calibration Frequency |
50 to 60 Hz |
Calibration Certificate |
Included |
Capacitance |
50 mF |
Frequency Counter |
100 KHz |
Battery Type |
9V |
Counts |
5,000 |
Includes |
Test Leads |
AC Response |
TRMS |
Auto Ranging |
Yes |
Data Hold |
Yes |
AC Current Accuracy |
+/-2.0% |
Operating Temp. |
32 Degrees to 122 Degrees F |
Audible Continuity |
Yes |
Data Logging |
Yes |
Special Features |
AC/DC Current via clamp with 0.1A resolution, Large Backlit display, Large jaw size for high Current measurements, Push button Zero adjust improves DC accuracy |
Standards |
CE |
Auto Power Off |
Yes |
Diode Test |
Yes |
Bluetooth Compatible |
No |
Maximum Operating Temperature |
122 Degrees F |
Frequency Measurement Resolution |
0.001 Hz |
Minimum Resistance Measurement |
400 ohm |
Instrument Safety Rating |
CAT IV 600V |
DC Voltage Measurement Resolution |
0.1 mV |
Features |
Data Logging |
Parameters Measured |
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Duty Cycle, Frequency, Resistance |
AC Current Measurement Resolution |
0.1 uA, 0.1 A |
AC Response Calculation |
TRMS |
Maximum Frequency Measurement |
100 kHz |
Removable Screen |
No |
Instrument Counts |
5,000 |
Waterproof |
No |
Basic AC Current Accuracy |
+/-2.00% |
Maximum DC Current Measurement |
2,000 A |
Display Type |
Backlit LCD |
Basic DC Current Accuracy |
+/-2.00% |
Minimum DC Current Measurement |
400 A |
Capacitance Measurement Resolution |
10 uF |
Maximum AC Current Measurement |
2,000 A |
Battery Access |
Yes |
Basic AC Voltage Accuracy |
+/-1.20% |
Maximum DC Voltage Measurement |
1,000 V |
Calibration Certificate Included |
Yes - NIST with Data |
Dustproof |
No |
Frequency Measurement Accuracy |
+/-1.00% |
Minimum AC Current Measurement |
400 A |
Minimum Operating Temperature |
32 Degrees F |
Thermal Imaging |
No |
Minimum AC Voltage Measurement |
4 V |
Minimum DC Voltage Measurement |
400 mV |
DC Current Measurement Resolution |
0.1 A |
Jaw Style |
Clamp-Jaw |
Resistance Measurement Accuracy |
+/-3.50% |
AC Voltage Measurement Resolution |
1 mV |
Batteries Included |
Yes |
Resistance Measurement Resolution |
0.1 ohm |
Intrinsically Safe |
No |
Maximum Resistance Measurement |
40 megaohm |
Current Leakage Testing |
No |
Maximum AC Voltage Measurement |
1,000 V |
Basic DC Voltage Accuracy |
+/-1.00% |
Capacitance Measurement Accuracy |
+/-3.00 % |
Maximum Capacitance Measurement |
50 uF |
Minimum Frequency Measurement |
5 Hz |