Item |
Megohmmeter |
Output Test Voltage |
100/250/500/1000V DC |
Insulation Resistance Range |
0.1 megaohm to 10 gigohm |
Accuracy |
+/-3% + 5 Digits |
Resistance Range |
0.1 to 999.9 ohm |
Display |
Backlit LCD with Bar Graph |
Features |
Already Calibrated, Dielectric Absorption, Polarization Index, Short Circuit Current Protection, Timer |
Power Source |
Battery, DC Adapter |
Includes |
(2) Plugs Test Lead to One Alligator Clip, (8) 1.5V C Batteries, Tool Box |
Data Logging |
18 Data Points |
Auto Ranging |
Yes |
Auto Power Off |
Yes |
Safety Rating |
Cat III 600V |
Calibration Certificate |
None |
Leakage Current Range |
Not Applicable |
Product Type |
Tester Only |
Communication Protocol |
Not Applicable |
Megohmmeter Features |
Data Logging |
CAT Safety Rating |
CAT II 1000V, CAT III 600V |
Parameters Measured |
AC Voltage, DC Voltage, Insulation Resistance, Low Resistance |
Display Type |
Digital |
Resistance Accuracy |
1% +/- 3 digits up to 999.9 ohm, 3% +/- 5 digits 1 kiloohm to 100 megaohm, 5% +/- 5 digits over 100 megaohm |
Waterproof |
No |
Minimum AC Current Measured |
Not Applicable |
Capacitance Auto Discharge |
Yes |
Test Voltage |
1,000V DC, 100V DC, 250V DC, 500V DC |
Digital Memory Capacity |
32KB |
Dustproof |
No |
Insulation Resistance Resolution |
0.1 megaohm to 10 gigaohm |
Maximum Ground Resistance Measurement |
Not Applicable |
Includes Batteries |
Yes |
Greater Than 30V Warning |
No |
Maximum Insulation Resistance |
10 gigohm |
Maximum DC Voltage Measured |
1,000 V |
Alert Type |
Light |
Minimum DC Voltage Measured |
30 V |
Includes Software |
No |
Minimum Capacitance Measured |
Not Applicable |
IP Rating |
Not Applicable |
Number of Batteries Required |
8 |
Minimum Operating Temperature |
14 Degrees F |
Bluetooth Compatible |
No |
Minimum Insulation Resistance |
0.1 megaohm |
Standards |
Not Applicable |
Live Circuit Voltage |
Greater Than25V AC |
Display Screen Type |
LCD |
Battery Chemistry |
Carbon Zinc |
Maximum Operating Temperature |
104 Degrees F |
Minimum Ground Resistance Measurement |
Not Applicable |
Test Current |
Less Than2mA |
Number of Records Stored |
18 |
Timed Ramp Voltage Test |
No |
Minimum DC Current Measured |
Not Applicable |
USB Data Download Included |
No |
Input Impedance |
10 megaohm |
PI/DAR Testing |
Yes |
Pass/Fail Selection Limits |
Yes |
Remote Test Probe Included |
No |
Backlit Digital Display |
Yes |
Testing Functions |
AC/DC Voltage, Insulation Resistance, Low Resistance |
Number of Digits |
4 |
Maximum DC Current Measured |
Not Applicable |
Low Resistance Range |
0.1 to 999.9 ohm |
Insulation Limit Alarm |
No |
Operating Voltage |
12V |
Maximum AC Voltage Measured |
750 V |
Data Logger |
Yes |
Maximum Capacitance Measured |
Not Applicable |
Minimum AC Voltage Measured |
30 V |
Maximum AC Current Measured |
Not Applicable |