Voltage |
120V AC |
Amps |
40 A |
Enclosure Type |
Steel |
Min. Time Setting |
1 hr |
Max. Time Setting |
23 hr |
Contact Form |
SPST |
Max. On/Off Cycles |
12 |
Extra Trippers |
2E054 |
Description/Special Features |
3R Enclosures in Steel or Noncorrosive Plastic, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day |
Time Setting Range |
1 hr. to 23 hr. |
Day Skipper |
No |
Nominal Max. Time Setting |
24 hr |
Contact HP @ 120V |
2 hp |
Contact HP @ 240V |
5 hp |
NEMA Rating |
3R |
Type |
24-Hour |
Number of Poles |
1 |
Number of Trippers Included |
2 |
Mount |
Hole Wall |
Finish |
Metal Enclosure has Gray Enamel |
Standards |
cCSAus, cULus |
Product Type |
Timer |
Operation Mode |
24 hour |
Electronic Ballast Load Ratings Ranges |
16 A, 120 VAC |
Application Compatibilities |
LED; HID |
Packaging Applications |
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps |
Has Manual Override CVL |
Yes |
Operating Temperature Min |
-40°C |
Power Consumption Max W |
3 W |
Minimum On Off Time |
1 hour |
UL Certification |
cULus |
Market |
Commercial; Industrial |
Inductive Load Ratings |
40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz |
Solutions |
Machinery & Pumps; Panel Integrators |
Motor Load Ratings |
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Skipper Wheel Operation Mode |
Not Included |
Maximum On Off Operations |
12 |
Electronic Ballast Load Ratings |
16 A, 120 VAC |
Operating Temperature Max |
130°C |
Input Voltage Ranges |
120 VAC, 60 Hz |
Tungsten Load Ratings Ranges |
40 A, 120-240 VAC, 60 Hz |
Pilot Duty Load Ratings |
1000 VA, 120-240 VAC, 60 Hz |
CSA Certification |
cCSAus |
Inductive Load Ratings Ranges |
40 A, 120-240 VAC, 60 Hz |
Tungsten Load Ratings |
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz |
UL Cerfication File Number |
UL917 |
Wiring Option |
Terminals |
Switch Type |
SPST |
Resistive Load Ratings Ranges |
40 A, 120-240 VAC, 60 Hz |
Number Of Circuits |
1 |
Applications |
Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control |
Resistive Load Ratings |
40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz |
Pilot Duty Load Ratings Ranges |
1000 VA, 120-240 VAC, 60 Hz |
Maximum ON/OFF Operations |
12 |
Operating Temperature Max (°F) |
130 |
Has Manual Override |
Yes |
Tungsten Range(s) |
40 A, 120-240 VAC, 60 Hz |
Operating Temperature Min (°F) |
-40 |
Inductive |
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Input Voltage Range(s) |
120 VAC, 60 Hz |
Features |
Manual Override |
Skipper Wheel |
Not Included |
Electronic Ballast |
16 A, 120 VAC |
Tungsten (NO) |
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Resistive |
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Pilot Duty (NO) |
1000 VA, 120-240 VAC, 60 Hz |
Motor Load Ratings Ranges |
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Minimum ON/OFF Times |
1 hour |
Maximum Power Consumption (W) |
3 W |
Operating Temperature Max (°F) |
130 |
Operating Temperature Min (°F) |
-40 |
Operating Temperature - Maximum |
130 Degrees F |
Mounting Style |
Surface |
Compatible Lighting |
HID, LED |
AC Voltage Rating |
120V AC |
Number of Trippers - Maximum |
2 |
Series |
T100 |
Operating Temperature - Minimum |
-40 Degrees F |
On/Off Cycles - Maximum |
12 |
Body Color |
Gray |
Current Rating - Maximum |
40 A |
Horsepower @ 240V - Maximum |
5 hp |
Body Material |
Metal |
Time Setting - Maximum |
24 hr |
NEMA Enclosure Rating |
3R |
Application |
Lighting |
Time Setting - Minimum |
1 hr |
Indoor/Outdoor Usage |
Indoor, Outdoor |
Horsepower @ 120V - Maximum |
2 hp |